Furnace and Heater Tube Inspections

by Ron Lucier, ASNT NDT Level III
ITC Logo TM 250 One of the more challenging applications of infrared thermography is in the measurement of process heater and furnace tubes. In fact we get dozens of inquiries each year from our clients on this very subject. Since this is a very complex subject it is probably appropriate to start from the beginning.
Process Heaters There are as many uses for process heaters as there are designs. The basic configuration consists of a shell (outer casing),   tubes (where the process fluid flows) and a heat source. These units are both thermodynamically and hydraulically complex.
Process heater or furnace diagram
In the simple drawing above we illustrate convective gas flow, which is turbulent, and radiant heat from the flame, refractory and other tubes – all non-uniform and time varying. When you view tube from an access port typically you can only see a portion of the tube or the tube at an oblique angle. Therefore, the odds are stacked against you from the start!
Why are heater tubes of interest anyway?
In the image to the right, a visual inspection yielded no indication of external slag or fouling, therefore the hot spots indicated are due to coke buildup on the inside of the tubes. This has caused the tube surface temperature to increase by 177 °F over the expected – and desired – temperature of 1100 °F.
Heater tube thermocoupleThe great emissivity debate To calculate the temperature you need to know the emissivity & background. To calculate the emissivity you need to know the temperature and background. Oops, we’re in an infinite loop!
The emissivity of the tube surface is very tough to determine and typically is derived from two sources – correlated to thermocouple measurements or folklore (“we’ve always assumed 0.88”). The former process is tough to accomplish but the preferred method. The latter has value in that existing trend data may exist. We are working on a better method of measuring process heater tube emissivity and will report on it in the future!

Simplified Heater Inspection Method The following method assumes that you have a mid-wave camera (3-5 ┬Ám) with a flame suppression filter installed. The process here was developed for a heater with vertical tubes.
Picture7Initial Camera Setup
  1. Use appropriate lens for distance and target size
  2. Flame Filter
  3. Extended Range
  4. Media Card installed
  5. Emissivity = 0.92
  6. Reflected apparent temperature setting – 1800° F
  7. Distance = 0.0 meters
  8. Auto Temperature Mode – Average
  9. Auto Temperature Area – Box
Image Acquisition
  1. Focus on far wall, store image
  2. Focus on far row of tubes, store image
  3. Focus on near row of tubes, store image
  4. Repeat for every other inspection port
Initial Measurement (done in the lab)
  1. Use emissivity = 1.0, measure far wall with Auto Temperature Box on Average.
  2. Enter that value for reflected apparent temperature.
  3. If you are looking NORTH, use the A value.
  4. If you are looking SOUTH, use the B value.
  5. This must be measured for each inspection port you look in.
Process Measurement
  1. Using the correct Background Temperature, set emissivity = 0.92, record tube temperatures.
  2. Set emissivity to 0.96, record a second set of temperatures.
  3. Report both values to give a range of temperatures (e.g. Tube 1-20 is between 1632 °F and 1641 °F)
Sample Thermal Images
Visible image of tubes
Tube measurements
Conclusion IR offers the operators of process heaters the ability to visualize the heat transfer that their point measurements are recording. There are probably many other methods used to gather this data.
Heater tubes 1There are several reasons for inspecting tubes. Qualitatively slag (scale) buildup on the outside of the tube can be readily identified. Buildup on the inside of the tube (coking) is a bit more difficult but commonly performed. In both cases the slag or coke prevents the transfer of heat into the process fluid. In the case of slag buildup, the process fluid may not be sufficiently heated, affecting downstream processing. The case of coking on the inside of the tube is more serious. Since the coke has an increased resistance to heat transfer, the tube surface temperature increases. After all it is the flow of the process fluid that is keeping the tube “cool” in the first place. In fossil boilers this is called “DNB” – Departure from Nucleate Boiling and is usually caused by flame impingement, which initiates a layer of steam on the inside of the tube. The external tube surface, unable to conduct its heat to the water, increases dramatically, causing a failure (opening) in the tube.

4 comments:

  1. Attaining Accurate IR data can be difficult as there are several variables that effect the examination. In my limited experience here are a few. In process heaters thermocouples have the potential to drift or not longer operate after several years of service (+- 100*F) or they are incorrectly installed. Another comment would be that the Emissivity seems to be a variable as it changes after time in service (scale). Also the flame pattern or transparency of it will also affect the accuracy of the data acquired. The data attained is essential to safe and efficient operation of various process heaters in today’s industry. That being said quality equipment and quality trained personnel are vital.

    Thanks

    ReplyDelete
    Replies
    1. You are absolutely correct. Thermocouples drift, decalibrate and decouple from the surface. An accurate and timely thermal image can spot trends such as the buildup of coke, flame impingement or excessive tube deformation (I have seen all three).

      Measuring emissivity is a challenge but when you go through the math, not as important as measuring the reflected temperature! This is because our target (tube) is cooler than it's environment (gas, radiant walls). The cameras are typically stated with a 2% accuracy. At 1000 degrees F that is 20 degrees. In most calculations it takes +/- 0.04 in emissivity to get that large a change in temperature! That isn't the case when the target is slightly warmer than the environment such as traditional building inspections.

      Science is always interesting!

      Ronald D. Lucier, ASNT Level III

      Delete
  2. Heating and air conditioning unit should be inspected regularly. These systems could be damaged if not cared properly. It is still a good idea to perform regular maintenance with the help of skilled HVAC technician. This will prevent any major problems that may arise in the future.Heating Service Cypress

    ReplyDelete
  3. The subject of infrared heaters has been covered intensively by the world press over the past decade. At first glance infrared heaters, may seem enchanting, however its study is a necessity for anyone wishing to intellectually advance beyond their childhood. Remarkably infrared heaters, is heralded by shopkeepers and investment bankers alike, leading many to state that it is yet to receive proper recognition for laying the foundations of democracy. Inevitably infrared heaters, is often misunderstood by those politically minded individuals living in the past, trapped by their infamous history. Here begins my in depth analysis of the glorious subject of infrared heaters,.