Wednesday, October 14, 2009

How Emissivity affects Heat Transfer and Surface Temperature


A reader writes:


"I know the higher the emissivity a surface has the greater its ability to absorb heat (IR), however, is a painted surface able to reject or shed heat better? An example would be does a painted engine run cooler than a unpainted metal engine or hotter or the same temp?"

If an object has a higher temperature than its environment, then increasing its emissivity will certainly lower its temperature. As an example, lets look at the motor in the illustration. It has a cover made of stainless steel and is very shiny. Let's assume its emissivity is 0.1.  We have measured its steady state temperature at 150 F. The rate of heat generation of the motor has to be exactly balanced by the rate of heat loss from the motor. So, in this case for simplification, we will only consider convection and radiation. The numbers are shown in the illustration.



Now, if we painted the motor with flat white paint, the heat transfer will change. We still have to get rid of the 66 Btu/hr being generated by the motor, but if we assume a new emissivity of 0.9, then the huge increase in the radiation loss will reduce the surface temperature to 118 F as shown.

Friday, October 9, 2009

IR Transparent Materials for Windows and Lenses

"Which material (Quartz or Sapphire) has better transparency to IR spectrum? Is there any material that is totally transparent to entire IR spectrum?"

The chart below illustrates a variety of materials and the wavelengths at which they transmit.


 



Here are detailed data sheets on quartz and sapphire.
"Which IR (Near IR or Far IR ) carries more thermal energy?"
Photons at shorter wavelengths of IR carry more energy. So all other things being equal, will produce more heating on an absorbing surface.
"While traveling through the IR transparent lens will be there any damage to the lens?"
Any infrared energy absorbed by the lens will produce some heating. Anti-reflective coatings are commonly applied to lens systems to reduce absorption and improve the transparency.

For more information please contact:

ISP Optics Corporation
1 Bridge Street, suite 205
Irvington, NY 10533, USA
Tel: 914-591-3070, 800-909-4207
Fax: 914-591-3715
E-mail: sales@ispoptics.com 
Web Site: http://www.ispoptics.com/


Monday, October 5, 2009

Check out the new Application Tracks at InfraMation

This year at InfraMation, we are introducing application tracks to make it easier for attendees to select the sessions that will best fit their needs at the conference. We have so many sessions and short courses, its impossible for anyone to attend them all. In fact out of the 36 technical sessions available, attendees only have time to attend a maximum of 16, less than half! Here are the tracks.

Buildings Track - Consists of 3 paper sessions, 1 panel discussion, and 6 short courses.

Condition Monitoring Track - 3 paper sessions, 4 panel discussions, and 8 short courses.

Medical Track - 3 paper sessions, 1 panel discussion, and 1 short course.

R&D Track - 3 paper sessions, 5 short courses.

You can find these tracks, subjects, and schedules in the at a glance chart to the right.
in reference to: Welcome to InfraMation - Thermographer's Conference (view on Google Sidewiki)

Friday, October 2, 2009

Marketing your infrared thermography services


This is an increasingly common request these days. As the prices of infrared cameras has dropped dramatically in the past few years, more and more independent consultants have been purchasing them. These users don't have large corporations and big marketing budgets to promote themselves.
"I love being a thermographer and would appreciate any suggestions you may have on how I can develop more effective ways to build my business?"


So you have to come up with smart low cost ways of getting noticed, and getting business. Here are a few suggestions:

Speak at local trade associations meetings. They are always looking for speakers. Some examples:
Call up or email local TV stations with interesting images or video you have taken with your IR camera. Examples:
  • Current news events - Forest fire, Search for lost child
  • Consumer concerns - Heating or A/C costs, Mold in schools
Build a web site and make sure search engines can find it

Find messageboards and blogs and contribute to them

Use social networking media like Linked In and Facebook to network

Search Business and Manufacturers Guides for potential clients
  • Shopping Centers
  • Office complexes
  • Warehouses
  • Supermarkets
  • Manufacturing Facilities
Here is an example of an online directory, Directories USA. You could search for parameters that could point to a good prospect such as:
  • Number of employees
  • Facilities Square footage
  • Electrical Useage
  • What they make
  • Plant Manager contacts
Put a video up on YouTube

Wednesday, September 30, 2009

Quick and Easy Solution to Emissivity Problems


"We've received the camera and so far it's been good in that department. I am concerned however about emissivity. In my application, I'm filming the inside of a computer system which is a small, tightly packed space with different materials and emissivities. Because thermography is something new to me, I'm not sure how much of a role emissivity plays in throwing off my measurements. I could attach a thermocouple to each component to verify the readings on the thermal cam, however that's very time consuming and given the limited amount of time I have with this instrument, it doesn't make sense. I've read that there's emissivity sprays that will help with this issue but don't know if that solution is any better or cost effective. Do you have any cheap and quick solutions for my problem?"

Yes, emissivity can play a big role in your temperature measurement accuracy, especially if you are trying to measure shiny metals. Here is what I would do:

Measure your reflected apparent temperature
  1. Set camera emissivity to 1.0
  2. Use some slightly crinkled aluminum foil and place next to your target(s).
  3. Using the area mode of your camera set to average temperature, read the apparent average temperature of the aluminum foil. (Be careful that you don't reflect your own heat reflection of the foil).
  4. Enter this temperature as the reflected temperature in your camera.
Measure your target(s)
  1. Use some Liquid Paper brand correction fluid.
  2. Place a small amount on your targets.
  3. Set your camera emissivity to 0.95
  4. Measure the temperature of your target(s)
Cautions and Caveats
  • When using these techniques make sure that the correction fluid will not damage your components.
  • Use a small amount of correction fluid. Changing the emissivity of small shiny components from less than 0.1 to 0.95 will greatly affect the heat transfer from these components, and thus affect their temperature. So the smallest amount of emissivity improver that you can measure is the amount to use. This is easy on FLIR systems cameras, just make sure that the emissivity improver is large enough to fill the cursor circle on the spot tool. Anything smaller will not be measured correctly.
  • There are more sophisticated ways of doing this automatically for all materials on a PCB through software. Please contact a FLIR Systems Scientific Segment Engineer regarding Altair software.
  • If you don't understand emissivity and reflected apparent temperature terms, get some training! A good place to start is this web based course, Thermography Basics.

How can one tell if the imager needs calibration?


Most manufacturers suggest that an IR camera be serviced with a calibration check annually, like many other instruments. The checklist below outlines the FLIR annual service program. 


FLIR 14 POINT INSPECTION & CALIBRATION PROGRAM
  1. Perform a complete operational check
  2. Fusion calibration and laser alignment, when applicable
  3. Verify all internal cable and PCB connections
  4. Clean viewfinder and check optics
  5. Upgrade internal camera software to latest revisions
  6. Perform minor repairs
  7. Verify and/or re-equalize as needed each temperature range for image uniformity
  8. Verify standard lens calibration (others or special engineered lenses, optional)
  9. Verify ambient temperature compensation as needed
  10. Re-calibration to ensure it meets factory specification
  11. Calibrate temperature ranges up to +1,500°C, when applicable
  12. Perform quality approved acceptance test procedure
  13. Provide calibration label with next due date
  14. Provide calibration certificate (optional, extended calibration certificate with measured values)

 Here is a quick way you can check your camera calibration in the field:
  1. Measure the temperature of a MELTING ice cube. The reading should be 0 C +/- 2 C.
  2. Measure the temperature of boiling water (if you are near sea level). Reading should be 100 C +/- 2 C

Tuesday, September 22, 2009

Thermography Weatherization Certification course earns BPI CEUs


The Weatherization certification course has been approved by BPI for 16 CEUS. It was previously approved by RESNET for 32 CEUS.

The 4 day certification course is intended to give the student a depth of the knowledge necessary to perform IR surveys of single or multifamily dwellings to identify weatherization issues. The class covers IR camera operation, and basic report generation, fundamentals of IR science and heat transfer principles. IR Weatherization surveys techniques, tips and tricks, and application examples.

More Information

Monday, September 21, 2009

How does the Lexus Driver Attention Monitor Work?

Here is how Lexus describes their Driver Attention Monitor:


"Mounted on the steering wheel column, a driver-monitor camera is part of the Advanced Pre-Collision System (APCS). It’s designed to recognize when the driver isn’t facing forward. If a frontal collision seems likely and the Driver Attention Monitor senses that the driver is not facing forward, a warning tone will sound, followed by a flashing light. "


While I don't have detailed specifications of the system, I believe that the system employs a near IR camera, working at the same wavelengths as an infrared remote control to view the drivers head. There might be an infrared LED providing illumination for the camera at night.


So I don't think this system is a LW IR camera as is typically used for thermography.

Friday, September 11, 2009

New Web Course: FLIR 600 Series Basics

This course provides an introduction to the operation of all variants of the FLIR 600 series cameras. These include the P620/640/660 and the B620/640/660. You will need to have your camera with you in order to obtain the maximum benefit from the camera operation exercises.

We highly recommend taking this course prior to taking the Thermography Basics, Building IR Basics, Level I, Weatherization, or Building Science courses.

Who should take this course: Users of FLIR 600 series cameras.

Prerequisites: No prior knowledge of thermography or infrared cameras is assumed.

Availability: This course is an on-demand self paced web based training course available 24 hours a day, 7 days a week. You can begin as soon as you enroll.

Link to the course